Standby Generators
Whole-home standby power, installed, serviced and load-tested.
Last updated
Outages here are not rare, and they are longest in exactly the weather that makes losing heat dangerous. A standby generator with an automatic transfer switch takes the house over within seconds and needs nobody at home to start it.
We size the generator to what you actually need to run — the whole house, or the essentials — install the transfer switch, and service the unit annually so it starts when it is finally asked to.
Standby Generators calls in Durango run out of our 178 Bodo Dr, Suite C office. We cover Durango, Bayfield, Ignacio, Hesperus, Mancos, Vallecito and the rest of La Plata County, and the Durango crew is on call 24 hours a day.
Standby and portable, and which problem each solves
A standby generator is permanently installed, runs on natural gas or propane, and starts itself. When the power fails, an automatic transfer switch disconnects the house from the utility and starts the generator, usually within about ten to thirty seconds, with nobody at home required.
A portable generator is cheaper, needs to be brought out, fueled, started and connected, and runs for as long as there is gasoline in it. It covers a few circuits rather than a house.
The question that usually decides it is what happens when the outage lands while nobody is home, in February. A freezer, a furnace and the pipes in an unheated crawlspace do not wait.
Sizing: the whole house, or the things that matter
Whole-house coverage means the generator carries everything, including air conditioning, and it is sized from a load calculation in the same way a service is.
Essential-circuits coverage is the more common choice and costs considerably less. A smaller generator feeds a sub-panel carrying the things that cause real damage or real misery when they stop: the furnace, the well pump, the refrigerator and freezer, a few lighting and outlet circuits, and the garage door.
The sizing detail that catches people out is motor starting. A well pump or an air conditioner draws several times its running current for the first moment, so a generator sized on running watts alone will stall when the pump kicks in at three in the morning.
How an automatic transfer switch works, and why it is not optional
The transfer switch is the part that makes a standby system safe. It physically prevents the house from being connected to the generator and the utility at the same time, and there is no arrangement of switches and habits that substitutes for it.
Without that separation, generator power can go back out through the service drop and energize the lines outside at full transformer voltage. That is backfeeding, and it is what kills utility crews working on what they have every reason to believe is a dead line. It is also what destroys the generator when the utility returns without warning.
The switch also handles the sequence: sensing the outage, starting the generator, waiting for it to stabilize, transferring the load, then transferring back and cooling down when the utility comes back.
Generac, and what a dealer relationship changes
We are a Generac dealer and service what we sell. That matters mostly for parts and warranty: a dealer can get a board or a controller without the unit sitting dead while one is sourced.
We install and service other manufacturers as well, so an existing generator from another brand is not a reason to start again.
Maintenance plans are available, and a standby generator is one of the few things where that genuinely decides whether it works. It runs a few minutes a week and is then asked to carry a house, usually on the worst night of the year.
The gas line is ours as well
A standby generator is two trades: an electrician for the transfer switch and the connection, a licensed plumber for the fuel. Our own plumbers run the gas, so the sizing, the permit and the pressure test are scheduled alongside the electrical rather than waiting on a second company.
That is usually what decides how long one of these jobs takes. The equipment lead time is the equipment lead time; the weeks people lose go to two contractors waiting on each other.
Natural gas or propane
Natural gas has no tank and no refueling, so a standby unit on a gas line runs as long as the outage does. Where there is no gas service, propane does the same job from a tank that has to be sized for the run time you want and kept filled.
Propane stores indefinitely without degrading, which gasoline does not, and that is a real advantage for equipment that may sit unused for a year. The trade-off is the tank, its placement and its clearances.
Either way a standby generator needs both a gas fitter and an electrician, which is worth knowing when comparing quotes that cover only one of the two.
Placement, noise and clearances
A standby unit needs clearance around it for airflow and service, distance from windows, doors and vents because it produces exhaust, and a level pad that will not settle. Manufacturers specify the distances and the inspection checks them.
Noise is the thing people underestimate. A standby generator at full load is loud enough to matter to a neighbor at two in the morning, and the weekly exercise cycle runs whether there is an outage or not. Placement that accounts for where the neighbors sleep avoids a conversation later.
Why a generator that is not maintained does not start
A standby generator spends its life waiting, and things that wait seize. The exercise cycle runs it briefly each week to circulate oil, charge the battery and keep seals from drying out.
The most common reason one fails to start when it is finally needed is the battery, which ages invisibly for years and is flat the one morning it matters. After that: old oil, a filter nobody changed, rodents in the enclosure, and a fuel supply that was never sized for full load.
An annual service with a load test is what distinguishes a generator that will run from one that merely starts. Starting is not the test; carrying the house is.
Running a portable generator safely
Two things cause the deaths. The first is backfeeding — connecting a portable generator to the house through a dryer outlet or a double-ended cord, which energizes the lines outside and can kill a lineman. The safe connection is an inlet with an interlock or a manual transfer switch, so the house cannot be connected to both sources.
The second is carbon monoxide. A portable generator produces it in quantity, and it has killed people running one in a garage with the door open, in a carport, and under an open window. Outdoors, well away from the building and away from anything that draws air in, is the only safe place for it.
Beyond that: let it cool before refueling, keep it dry and off wet ground, and use cords rated for the load and the distance.
What this covers
- Standby generator installation
- Automatic transfer switches
- Portable generator hook-ups
- Annual service
- Load testing
- Emergency generator repair

Towns we cover from Durango
Questions
Standby Generators in Durango
How long does a standby generator take to come on?
Typically about ten to thirty seconds. The transfer switch senses the outage, starts the generator, waits for it to stabilize, then transfers the house across. Nobody has to be home. When the utility returns the switch transfers back and lets the generator cool down before shutting off.
What size generator do I need?
It depends on whether you want the whole house or the essentials, and the sizing comes from a load calculation rather than a rule of thumb. The detail that catches people out is motor starting: a well pump or air conditioner briefly draws several times its running current, so a generator sized on running watts alone will stall when the pump starts.
Can I just plug a portable generator into an outlet?
No. Connecting a generator to the house through an outlet or a double-ended cord sends power back out through the service and can energize the lines outside at full voltage, which is what kills utility crews. The safe connection is a generator inlet with an interlock, or a manual transfer switch, so the house can never be connected to both sources at once.
Natural gas or propane?
Natural gas means no tank and no refueling, so the generator runs as long as the outage lasts. Propane does the same job where there is no gas service, from a tank sized for the run time you want, and it stores for years without degrading the way gasoline does. Both need a gas fitter as well as an electrician.
Why does my generator run every week?
That is the exercise cycle, and it is deliberate. A short weekly run circulates oil, keeps the battery charged and stops seals drying out. The most common reason a standby generator fails during a real outage is a battery that has quietly aged, which is exactly what the cycle and an annual service are there to catch.
How often does a standby generator need servicing?
Annually is the normal interval, and the service is worth more than the start. Oil and filters, the battery, the enclosure and the fuel supply all get checked, and a load test proves the unit will carry the house rather than merely run. A generator that starts on no load has not been tested.
Who runs the gas line for a standby generator?
Our own licensed plumbers. That is the practical advantage of four divisions under one roof — the electrical and the gas work get scheduled together rather than left for you to coordinate between two companies, and one company is accountable for the result.
Need standby generators in Durango?
Most repairs are finished on the first visit. Emergency crews run 24/7 across the Four Corners.